A Drum Humidifier’s output is controlled by the humidistat, which monitors the home’s relative humidity and activates or deactivates the unit accordingly. Inside the humidifier, a rotating evaporator pad (or drum) lifts water from the water pan into the air stream, which is warmed and circulated by the furnace blower.
Because Skuttle Drum Humidifiers rely on forced air, they are well suited for warm-air heating systems, including gas, gas high-efficiency, electric, heat pump, geothermal, solar and oil forced air systems.
Moisture Output Capacity
Temp (Warm Air Duct) | Lbs/Hour | Gal/Hour | Gal/Day |
86 @ 120°F | 5.91 | 18.5 | |
86 @ 110°F | 5.46 | 15.7 | |
86 @ 100°F | 4.69 | 13.5 | |
90 | 5.91 | 0.71 | 17.0 |
190 | 5.91 | 0.71 | 17.0 |
Model 90/190 Bypass Specifications
90 Dimensions 10-15/16”H x 10-3/4”W x 11-11/16”D
90 Plenum Opening 6-5/8”H x 8-1/2”W
190 Dimensions 10-3/4”H x 10-3/4”W x 10-5/8”D
190 Plenum Opening 7”H x 8-1/2”W
Bypass Opening/Tubing 6” diameter
Drum Motor 24 VAC, 3 watt, 1 RPM, bidirectional
Evaporator Pad 8-7/16”OD [6-11/16”ID] x 7-7/8”W
Pad Replacement A04-1725-034
Model 86 Under Duct Specifications
Dimensions 6-3/8”H x 15-1/4”W x 19-1/2”D
Extension into Duct 3-1/4”
Extension below Duct 6-3/8”
Duct Opening 12” x 16”
Minimum Duct Width 12”
Solenoid 24VAC, 3 watt, 1 RPM, bidirectional
Evaporator Pad 8-3/16”OD [6-11/16” ID] x 9”W
Evaporator Pad Replacement No. A04-1725-050
Model 86 Under Duct Specifications
Dimensions 6-3/8”H x 15-1/4”W x 19-1/2”D
Extension into Duct 3-1/4”
Extension below Duct 6-3/8”
Duct Opening 12” x 16”
Minimum Duct Width 12”
Solenoid 24VAC, 3 watt, 1 RPM, bidirectional
Evaporator Pad 8-3/16”OD [6-11/16” ID] x 9”W
Evaporator Pad Replacement No. A04-1725-050
Model | Tight House | Loose House |
Square Feet | 4,048 | 1,848 |
Cubic Feet | 32,381 | 14,783 |
Unique snap-lock fittings and reversible components permit versatile installation
Mountable on horizontal ducts as small as 12” wide and 8” high
Although Skuttle Drum units require more maintenance than other humidifier types, they are designed for easy cleaning and pad replacement by either the homeowner or servicing contractor. At a minimum, the humidifier and pad need to be cleaned at the end of every humidifying season. Mineral buildup on the pad may necessitate mid-season cleaning, as well. The humidifier and the connecting water valve must be turned OFF at the end of each heating season.